type: Procedure
title: Assess an aeroponic root chamber before planting
description: An evidence and equipment readiness check; incomplete inputs remain explicit stop conditions.
status: draft
sources:
- id: cip-aeroponics-2010
  title: Manual on quality seed potato production using aeroponics — Víctor Otazú, International Potato
    Center (2010)
  resource: https://cipotato.org/wp-content/uploads/2014/08/005447.pdf
steelthumb:
  ontology_version: '0.2'
  license: MIT
  claims:
  - id: coverage-check
    kind: recommendation
    statement: After transplanting, CIP checks that roots receive nutrient spray and that plant openings
      do not admit light into its boxes.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Plant and nutrient handling, printed p. 33
  - id: hardware-test
    kind: recommendation
    statement: CIP advises testing available nebulizer types before selecting the units for an installation.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Timers and other components, printed p. 27
  - id: backup
    kind: recommendation
    statement: CIP calls for standby power and a spare pump, with an effective response when the operating
      supply fails.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Electricity and plumbing, p. 26; Timers, p. 27
  - id: many-wilt
    kind: recommendation
    statement: When most plants wilt, CIP’s troubleshooting checks inadequate pressure and clogged pump
      inlet or filters.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Troubleshooting chart, printed p. 42, Most plants in aeroponics are wilting
  - id: local-wilt
    kind: recommendation
    statement: When only some plants wilt, CIP checks nearby nebulizers for blockage; when spray is adequate,
      it checks for stem damage.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Troubleshooting chart, printed p. 42, Some plants in boxes wilting; Plant wilting even
        with enough fogging
  - id: rapid-emptying
    kind: recommendation
    statement: An unexpectedly fast-emptying tank calls for checking leaks and a blocked return-drain
      opening in CIP’s system.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Troubleshooting chart, printed p. 42, Tank becomes empty unusually soon
  - id: calibration
    kind: recommendation
    statement: CIP identifies instrument calibration as a check when pH or EC measurements are inconsistent.
    applicability:
      conditions: CIP 2010 recirculating aeroponic seed-potato boxes; general equipment checks are explicitly
        adapted when applied to other crops.
    evidence:
    - source_id: cip-aeroponics-2010
      relation: supports
      locator: Troubleshooting chart, printed p. 42, Measurements of pH or EC not consistent
  relations:
  - predicate: applies_to
    target: /systems/aeroponic-root-chambers.md
---

# Assess an aeroponic root chamber before planting

Use this with the [system description](../systems/aeroponic-root-chambers.md) and a selected crop protocol. The output is a documented readiness decision, not a seed-to-harvest recipe or proof of crop performance. CIP's seed-potato equipment checks inform this assessment; using them for lettuce is an editorial transfer of mechanical checks, not a validated lettuce protocol.

Have the actual chamber and delivery design, equipment instructions, crop identity/stage, water analysis, nutrient formulation, measurement instructions, cleaning plan and backup plan available. Review [the lettuce evidence](../guides/aeroponic-lettuce-evidence.md) before treating a published timer or EC as a transferable recipe.

## 1. Confirm the operating specification

Record the crop and harvest purpose, starting material, root support, crop spacing, light and separate air/root-zone temperature requirements. Identify the entire nutrient recipe, stock strength and final solution volume; retain water chemistry and the intended pH/EC measurement method. A nominal EC cannot identify a fertilizer formulation. Missing crop or recipe inputs require resolution before stocking the system.

Record pump, nozzle, filter, operating pressure/flow, on-time, start-to-start interval or explicit off-time, reservoir and drain arrangement. Distinguish an interval from an off-period. List any retained water layer. Nozzle droplet specification and actual coverage cannot be inferred from a marketing name.

## 2. Check delivery and return before planting

<a id="coverage-check"></a>
After transplanting, CIP checks that roots receive nutrient spray and that plant openings do not admit light into its boxes.[^cip-aeroponics-2010]

<a id="hardware-test"></a>
CIP advises testing available nebulizer types before selecting the units for an installation.[^cip-aeroponics-2010]

Editorial commissioning sequence: run the empty system according to its equipment instructions; observe every planting position, return flow, connections and tank level over complete programmed cycles. Confirm how nozzle access and cleaning will work after roots grow. Repeat the coverage check when the actual seedlings are installed; a free-running nozzle can be obstructed by a root mass. Do not place plants in a system with unexplained dry positions, leaks or flooding.

## 3. Confirm failure response

<a id="backup"></a>
CIP calls for standby power and a spare pump, with an effective response when the operating supply fails.[^cip-aeroponics-2010]

Document who can respond, the replacement/backup equipment and the supplier's restart procedure. Before adding plants, exercise the intended backup under an equipment-appropriate test and confirm that delivery resumes at all positions. This is an editorial readiness test; it supplies no universal safe outage duration. CIP's seed-potato examples are not evidence that lettuce can wait a stated number of minutes without mist.

## 4. Establish observation and troubleshooting

<a id="many-wilt"></a>
When most plants wilt, CIP’s troubleshooting checks inadequate pressure and clogged pump inlet or filters.[^cip-aeroponics-2010]

<a id="local-wilt"></a>
When only some plants wilt, CIP checks nearby nebulizers for blockage; when spray is adequate, it checks for stem damage.[^cip-aeroponics-2010]

<a id="rapid-emptying"></a>
An unexpectedly fast-emptying tank calls for checking leaks and a blocked return-drain opening in CIP’s system.[^cip-aeroponics-2010]

<a id="calibration"></a>
CIP identifies instrument calibration as a check when pH or EC measurements are inconsistent.[^cip-aeroponics-2010]

Record actual solution temperature, pH/EC, tank level, delivery and root/leaf condition at the frequency required by the selected crop/equipment plan. Respond promptly to loss of delivery. The published source checks suggest where to investigate; they do not diagnose every wilted plant. With many affected plants inspect common supply first; with a local cluster inspect its nozzle and support. Isolate equipment as its instructions require before cleaning or replacing parts, restore the intended delivery and compare subsequent plant condition. Persistent wilt despite adequate delivery needs a separate root, nutrient or pathogen assessment.

When water disappears unexpectedly, inspect the entire return path as well as the tank. If instruments disagree, confirm calibration before adjusting nutrient concentration or pH. Do not copy the manual's historical pesticide or acid-dosing directions into another crop's system. Obtain the current crop/product-specific protocol for any such intervention.

## Result and follow-up

Record **ready for the specified crop protocol**, **not ready**, or **unresolved**. Ready requires a complete crop/recipe specification, demonstrated delivery and return, usable monitoring/cleaning access and a working failure response. This checklist cannot supply the missing protocol: the currently linked lettuce research examples remain incomplete as home-growing instructions.

Repeat the relevant checks after transplanting, equipment changes, cleaning, outages and root growth that changes coverage. Keep operating observations separate from intended settings and any later crop outcome. [Source inspection](../sources/aeroponic-systems-research.md).


[^cip-aeroponics-2010]: [Manual on quality seed potato production using aeroponics — Víctor Otazú, International Potato Center (2010)](https://cipotato.org/wp-content/uploads/2014/08/005447.pdf).